Vista DSM™ Wall Unit Installation

Insert two (2) Vista DSM™ Alignment pins per block unit on the base course. Place the next course of wall units in a staggered position maintaining tight connections between blocks. Repeat pin installation at each course and continue unit installation to height of wall or maximum grout level. As per design requirements, place horizontal locating rebar at required heights from end to end making sure not to splice or overlap this rebar. Straighten and align wall construction every 4 feet or as needed using a string line and blow hammer. If during Vista DSM™ unit installation, blocks become uneven or inconsistent, grid or shim units to maintain level transitions.

I N S T A L L A T I O N